● 256 MB DRAM with ECC memory |
● 1 GB removable SD flash memory card (CG swap drive)–(128MB space available) |
● Mini-USB connector |
Alarm |
● Alarm I/O: two alarm inputs to detect dry contact open or closed, one alarm output relay. 48 VDC, 0.5A max |
Power Supply |
● Redundant DC input voltage with operating range: 12-48 VDC Nominal, 9.6-60 VDC Maximum |
● Maximum DC input current: 0.5A at 48 VDC, 1A at 24 VDC |
Power Consumption |
● 6-port models: 9.5-15 W |
● 10-port models: 11-16 W |
● 20-port models: 13-20 W |
Dimensions (H×W×D), Including DIN Rail |
● IE-2000U 6 ports (copper downlinks) chassis: 5.1×2.95×4.51 in (130×74.9×115 mm) |
● IE-2000U 6 ports (SFP downlinks) chassis: 5.1×3.15×4.51 in (130×80×115 mm) |
● IE-2000U 10 ports: 5.1×3.6×5.26 in (130×91.4×134 mm) |
● IE-2000U 20 ports: 5.1×5.0×5.26 in (130×127×134 mm) |
Weight |
● IE-2000U 6 ports (copper downlinks) chassis: 2.45 lbs (1.11 kg) |
● IE-2000U 6 ports (SFP downlinks) chassis: 2.69 lbs (1.22 kg) |
● IE-2000U 10 ports long chassis: 3.45 lbs (1.56 kg) |
● IE-2000U 20 ports chassis: 4.35 lbs (1.97 kg) |
Per port per VLAN ingress policing |
Resilient Ethernet Protocol |
SCADA protocol classification using ACLs |
FlexLink |
Per GOOSE VLAN classification/statistics |
Link-state tracking |
Configurable egress queue bandwidth |
UDLD |
Configurable egress buffers/thresholds |
xSTP: 802.1s/802.1w |
Strict priority queuing with optional policer |
EtherChannel/LACP/Port Aggregation Protocol (PAgP) |
Web- and MAC-based authentication |
External alarm contacts |
Port security plus Cisco enhancements |
Modbus memory map support |
DHCP snooping, dynamic ARP inspection, IP source guard |
FEFI |
Spanning Tree Protocol security mechanisms |
Cisco Configuration Professional |
Storm control |
Utility-specific Smartport macros |
Wire-speed L2-L4 ACLs |
DHCP autoconfig/image upgrade |
Private VLAN |
Config rollback/replace |
Secure connectivity: SSH/SSL/SCP |
SPAN/RSPAN |
RADIUS/TACACS+ |
Layer 3 IP SLA |
SNMPv3 crypto |
GOLD |
Configuration file security |
OBFL |
UNI/ENI and NNI port types (configurable on all ports) |
Time Domain Reflectometry (copper ports) |
Configurable per VLAN MAC learning |
Digital Optical Monitoring (DOM), optical ports |
MAC address learning and aging notifications |
Ethernet OAM |
Configurable control plane security |
Connectivity Fault Management (CFM) |
IEEE 802.1x and identity-based network services |
IEEE 802.1ag Ethernet in the first mile (EFM) |
IEEE 802.1AR for hardware-based security |
IEEE 802.3ah Ethernet LMI (PE) -MEF |
Ethernet LMI (CE): MEF |
CFM to E-LMI Interworking |
CFM to EFM Interworking |
802.1ag plus IPSLA (Ethernet SLAs) |
Parallel Redundancy Protocol(PRP) |
PoE and PoE+ |
IP Services |
|
Static routing, Inter-VLAN routing |
HSRP |
Multi-VRF CE (VRF-lite) |
Multicast routing: PIM (SM, DM) |
Policy-based routing |
Source Specific Multicast |
RIP Versions 1 and 2 |
Source Specific Multicast mapping |
EIGRP, OSPF, and IS-IS |
Bidirectional Forwarding Detection |
BGPv4 |
Multicast support for VRF (mVRF-Lite) |
IPv6 routing |